Wandmontierter Heißluftgenerator Lodos 35
Gas

Wandmontierter Heißluftgenerator - Lodos 35 - Daygas Heating Systems - Gas
Wandmontierter Heißluftgenerator - Lodos 35 - Daygas Heating Systems - Gas
Wandmontierter Heißluftgenerator - Lodos 35 - Daygas Heating Systems - Gas - Bild - 2
Wandmontierter Heißluftgenerator - Lodos 35 - Daygas Heating Systems - Gas - Bild - 3
Wandmontierter Heißluftgenerator - Lodos 35 - Daygas Heating Systems - Gas - Bild - 4
Zu meinen Favoriten hinzufügen
Zum Produktvergleich hinzufügen

Eigenschaften

Typ
wandmontiert
Zufuhr
Gas
Leistung

3.500 W

Beschreibung

Daygas combines efficient, economical, high-quality, and functional products that prioritize innovation and R&D, saving energy in the heating sector for end users.Cooling mode.Quick start.Low-noise operation.Low emission value.High safety level.Secure gas valve system.Low energy consumption.5-stage operation with thermostats or remote control.Error message and stage display on the screen.Specially designed boiler for increased efficiency.Capacity35kWGas consumptionNG 3.33m³/h / LPG 2.46 kg/hDimensions660h / 660L / 820wWeightNet 49.00kg / Gross 54.00kgOperating pressureNG 21-55mbar / LPG 32-55mbarHeating area (surface)min 176m² / avg 220m² / max 264m²Heating area (volume)min 528m³ / avg 660m³ / max 792m³Sound level in empty room55 dBASound level at workplace43 dBAAirflow3500m³Electrical connection (EU)190-260 V / 50-60 HzGas connectionG ¾’’Homogeneous Heat DistributionLodos hot air generators heat areas requiring direct convection with a technological burner structure that emits minimal exhaust gases. The heat generated in the high-efficiency blades is transferred directly to the medium by an axial fan, making them devices with the most homogeneous heat distribution.Space-Saving DesignDaygas Lodos hot air generators transfer heat energy from NG or LPG either directly to the environment where the fan is mounted or by blowing hot air through air ducts. Thanks to a specially developed boiler structure, they offer high efficiency and low energy consumption. The special design ensures the lowest operating noise level with the boiler and housing structure, operating more quietly than competitors. For efficient and homogeneous heating, it is recommended to use hot air generators in confined spaces with ceiling heights not exceeding 5 m.Possibility to operate hermetically and semi-hermetically.Electrical components made of high-temperature resistant, non-flammable silicone cables.All metal components made of high-temperature resistant, durable aluminum-silicon alloy.Device ControlVarious scenarios and control elements are associated with device control, including:Remote controlIntegration via control panelPako switched manual controlThermostat-controlled automatic controlIntegration into automation systems (SCADA control)The diversity of control scenarios, offered as 5 different alternatives, allows products to be controlled correctly and as desired. The most suitable control scenario is selected by evaluating the on-site use and location conditions. Proper control facilitates both fuel savings and long-lasting, trouble-free operation.Integration into Automation Systems (SCADA Control)Devices can be integrated directly into building management systems (BMS) via the Modbus communication protocol over the RS485 port (internal). If no BMS is available, device control can be fully automatic from a single center via an HMI touch panel or PC.Device operating sequence on specified days and hoursOperation of heating devices with regional or individual step and modulation controlDisplay of device error codes in the system for identification and memory storageFunctional controls such as immediate, daily, weekly, or monthly monitoring of fuel consumptionControl Units128x64 graphic LCD displayAutomatic and manual controlCommunication port with computerOption to connect an external temperature sensorAbility to control 8 independent zones and up to 32 devices7 days, 24 hours programmable functionOverheat protection modeFrost protection functionEncrypted protection functionFacilitates operation with many commands, from controlling device on/off at desired workdays and intervals to maintaining a warm environment within the set frost protection temperature range when the business is closed.Analog Room ThermostatWith the Daygas analog room thermostat, the device automatically switches off when the set temperature is reached. If the room temperature drops below the desired value, the device automatically switches on at maximum level and resumes operation, saving fuel.Digital Room ThermostatFrost protection functionTemperature control on the deviceModulation control capabilityWhen devices reach the programmed temperature with the Daygas temperature sensor, the modulation value is reduced according to weather conditions, saving fuel. Once the desired temperature is reached, the device switches off automatically; if the temperature drops, it switches on and operates at the most suitable level for the environment.Pako Switched Manual ControlStepwise manual control can be provided via the Pako switch. For more local solutions where no control panel is present or needed, devices can be operated at the desired level via the Pako switch. Heating devices can be controlled with independent step settings. In standby mode (0), the device is not switched on, ensuring long service life.Remote ControlWith the Daygas remote control, all device functions such as on/off, temperature increase/decrease, and reset can be easily controlled. All Daygas products can be controlled remotely with a single remote.Homogeneous heat distributionSpace-saving designLow noise operationHigh efficiency and low energy consumptionMultiple control options: remote, panel, manual, thermostat, automationSuitable for confined spaces with ceiling height up to 5 mTechnical Specifications / FeaturesCapacity: 35kWGas consumption: NG 3.33m³/h / LPG 2.46 kg/hDimensions: 660h / 660L / 820wWeight: Net 49.00kg / Gross 54.00kgOperating pressure: NG 21-55mbar / LPG 32-55mbarHeating area (surface): min 176m² / avg 220m² / max 264m²Heating area (volume): min 528m³ / avg 660m³ / max 792m³Sound level in empty room: 55 dBASound level at workplace: 43 dBAAirflow: 3500m³Electrical connection (EU): 190-260 V / 50-60 HzGas connection: G ¾’’

Kataloge

* Die Preise verstehen sich ohne MwSt., Versandkosten und Zollgebühren. Eventuelle Zusatzkosten für Installation oder Inbetriebnahme sind nicht enthalten. Es handelt sich um unverbindliche Preisangaben, die je nach Land, Kurs der Rohstoffe und Wechselkurs schwanken können.